| Tekniske Data | 50 Hz | Combi BRV (R 5/Panda) | | BRV 0500 A/0165 | BRV 0500 A/0255 | BRV 1000 A/0255 | BRV 1000 A/0305 | BRV 2000 A/0305 | BRV 2000 A/0630 | BRV 4000 A/0630 | | Roots | | Panda WV 0500 B | Panda WV 0500 B | Panda WV 1000 B | Panda WV 1000 B | Panda WV 2000 C | Panda WV 2000 C | Panda WV 4000 A | | Backingpumpe | | RA 0165 D | RA 0255 D | RA 0255 D | RA 0305 D | RA 0305 D | RA 0630 B | RA 0630 B | | Leveringsmengde ved 1 hPa (mbar) | m³/t | 445 | 450 | 880 | 905 | 1660 | 1810 | 3560 | | Sluttrykk | hPa (mbar) | < 1/10² | < 1/10² | < 1/10² | < 1/10² | < 1/10² | < 1/10² | < 1/10² | | Nominell motoreffekt | kW | 5.5 | 7.0 | 8.5 | 10.5 | 13.0 | 20.5 | 26.0 |
| Tekniske Data | 60 Hz | Combi BRV (R 5/Panda) | | BRV 0500 A/0165 | BRV 0500 A/0255 | BRV 1000 A/0255 | BRV 1000 A/0305 | BRV 2000 A/0305 | BRV 2000 A/0630 | BRV 4000 A/0630 | | Roots | | Panda WV 0500 B | Panda WV 0500 B | Panda WV 1000 B | Panda WV 1000 B | Panda WV 2000 C | Panda WV 2000 C | Panda WV 4000 A | | Backingpumpe | | RA 0165 D | RA 0255 D | RA 0255 D | RA 0305 D | RA 0305 D | RA 0630 B | RA 0630 B | | Leveringsmengde ved 1 hPa (mbar) | m³/t | 535 | 540 | 1045 | 1085 | 1990 | 2170 | 4270 | | Sluttrykk | hPa (mbar) | < 8/10³ | < 8/10³ | < 8/10³ | < 8/10³ | < 8/10³ | < 8/10³ | < 8/10³ | | Nominell motoreffekt | kW | 7.7 | 9.7 | 11.5 | 11.5 | 15.0 | 26.0 | 31.0 |
| Tekniske Data | 50 Hz | Combi BNV (COBRA/Panda) | | BNV 0500 A/0100 | BNV 0500 A/0200 | BNV 1000 A/0200 | BNV 1000 A/0400 | BNV 2000 A/0400 | BNV 2000 A/0630 | BNV 4000 A/0630 | | Roots | | Panda WV 0500 B | Panda WV 0500 B | Panda WV 1000 B | Panda WV 1000 B | Panda WV 2000 C | Panda WV 2000 C | Panda WV 4000 A | | Backingpumpe | | NC 0100 B | NC 0200 B | NC 0200 B | NC 0400 B | NC 0400 B | NC 0630 B | NC 0630 B | | Leveringsmengde ved 1 hPa (mbar) | m³/t | 430 | 455 | 880 | 905 | 1740 | 1800 | 3500 | | Sluttrykk | hPa (mbar) | < 5/10³ | < 5/10³ | < 5/10³ | < 5/10³ | < 5/10³ | < 5/10³ | < 5/10³ | | Nominell motoreffekt | kW | 5.5 | 7.0 | 8.5 | 10.5 | 13.0 | 20.5 | 26.0 |
| Tekniske Data | 60 Hz | Combi BNV (COBRA/Panda) | | BNV 0500 A/0100 | BNV 0500 A/0200 | BNV 1000 A/0200 | BNV 1000 A/0400 | BNV 2000 A/0400 | BNV 2000 A/0630 | BNV 4000 A/0630 | | Roots | | Panda WV 0500 B | Panda WV 0500 B | Panda WV 1000 B | Panda WV 1000 B | Panda WV 2000 C | Panda WV 2000 C | Panda WV 4000 A | | Backingpumpe | | NC 0100 B | NC 0200 B | NC 0200 B | NC 0400 B | NC 0400 B | NC 0630 B | NC 0630 B | | Leveringsmengde ved 1 hPa (mbar) | m³/t | 520 | 545 | 1055 | 1080 | 2085 | 2160 | 4200 | | Sluttrykk | hPa (mbar) | < 3/10³ | < 3/10³ | < 3/10³ | < 3/10³ | < 3/10³ | < 3/10³ | < 3/10³ | | Nominell motoreffekt | kW | 6.2 | 9.2 | 11.5 | 13.2 | 16.7 | 22.5 | 27.5 |
 |
|
|